Don't Miss

DuROCK PUCCS

PUCCS NC (NON-COMBUSTIBLE)

DuROCK’s PUCCS NC is the latest addition to the PUCCS series of Exterior insulated Finish Systems. The GDDC circular grooved PUCC-ROCK virgin wool insulation board has a 10mm deep air space required by building code and professional insurers. PUCC-ROCK non-combustible insulation and its integral reinforcing mesh are simultaneously fastened to the supporting wall using DuROCK’s liquid applied WRB’s and mechanical fasteners. The PUCC-ROCK insulation board effectively forms a water-repellant gasket around each fastener. PUCC-ROCK insulation boards are face-marked at 4 inch intervals to pinpoint stud locations, which makes this system much easier and faster to install. PUCCS NC has dual reinforcing meshes for increased impact resistance. PUCCS NC liquid-applied WRB’s effectively control air leakage, yet permit vapour diffusion to the exterior. PUCCS NC can be easily detailed to direct precipitation to the exterior.

3D DETAILS

> 3D DETAIL FULL PACKAGE

> COVER PAGE

> PUCC-ROCK INSULATION BOARD DETAIL

> WINDOW HEADER OPTIONS

> WINDOW SILL AND JAMB

> HORIZONTAL EXPANSION JOINT OPTIONS

> TERMINATION AT GRADE AND FLAT ROOF

> TERMINATION AT BALCONY

> OUTSIDE CORNER TREATMENT

OTHER DOCUMENTS

> SPECIFICATION

> AUTOCAD DRAWINGS

2D DETAILS

> 2D DETAIL FULL PACKAGE

> COVER PAGE

> WINDOW HEADER WITH PVC UNI FLASH

> WINDOW HEADER WITH METAL FLASHING

> WINDOW SILL

> WINDOW JAMB

> HORIZONTAL EXPANSION JOINT (SEALED)

> HORIZONTAL EXPANSION JOINT (DRAINED)

> TERMINATION AT GRADE

> TERMINATION AT FLAT ROOF

> TERMINATION AT BALCONY SLAB

> OUTSIDE CORNER DETAIL

PUCCS EIFS FOR COMMERCIAL AND HIGH RISE

PUCCS is continuous insulation cladding that includes a Geometrically Defined Drainage Cavity (GDDC) that is 10 mm deep and 37% open. PUCCS complies with National Building Code of Canada Subsection 5.9.4 (OBC 5.10.3) and Subsection 9.27.13, PUCCS complies with the CAN/ULC-S716.1 EIFS Materials and Systems test standard, PUCCS satisfies the test criteria in National Building Code of Canada Article 3.1.5.5 when tested in accordance with CAN/ULC-S134, and PUCCS satisfies the test criteria in National Building Code of Canada Article 3.2.3.8 when tested in accordance with CAN/ULC-S101.

3D DETAILS

> 3D DETAIL FULL PACKAGE

> STANDARD WALL SECTION

> D01 Moisture Barrier Adhesive Combinations

> D02 Window Rough Opening Treatment

> D03 Window Header Options

> D04 Window Sill and Jamb

> D05 Horizontal Expansion Joint Options

> D06 Termination at Grade & Flat Roof

> D07 Termination at Balcony

> D08 EIFS Soffit & Roof Top Parapet

> D09 Wall Exhaust & Scupper Penetration

> D10 Signage & Down Spout Attachment

> D11 Aesthetic Reveal Options

OTHER DOCUMENTS

> SPECIFICATION

> AUTOCAD DRAWINGS

> CCMC EVALUATION

2D DETAILS

> 2D DETAIL FULL PACKAGE

> STANDARD WALL SECTION

> D01 Window Header With PVC Uni Flash

> D02 Window Header With Metal Flashing

> D03 Window Sill Detail

> D04 Window Jamb Detail

> D05 Horizontal Expansion Joint Sealed

> D06 Horizontal Expansion Joint Drained

> D07 Termination at Grade

> D08 Termination at Flat Roof

> D09 Termination at Balcony Slab

> D10 Termination at EIFS Soffit

> D11 Termination at Roof Top Parapet

> D12 Wall Exhaust Penetration

> D13 Scupper Penetration

> D14 Signage Attachment

> D15 Aesthetic Reveals

PUCCS EIFS FOR RESIDENTIAL AND LOW RISE

PUCCS is continuous insulation cladding that includes a Geometrically Defined Drainage Cavity (GDDC) that is 10 mm deep and 37% open. PUCCS complies with National Building Code of Canada Subsection 5.9.4 (OBC 5.10.3) and Subsection 9.27.13, PUCCS complies with the CAN/ULC-S716.1 EIFS Materials and Systems test standard, PUCCS satisfies the test criteria in National Building Code of Canada Article 3.1.5.5 when tested in accordance with CAN/ULC-S134, and PUCCS satisfies the test criteria in National Building Code of Canada Article 3.2.3.8 when tested in accordance with CAN/ULC-S101.

3D DETAILS

> 3D DETAIL FULL PACKAGE

> STANDARD WALL SECTION

> D01 Alternate Rough Opening Treatment

> D02 Window Header Options

> D03 Window Sill Options

> D04 Window Jamb & Vertical Expansion Joint

> D05 Horizontal Expansion Joint Options

> D06 Termination at Deck

> D07 Termination at Sloped Roof

> D08 Termination at Concrete Sill Option 1 & 2

> D09 Termination at Concrete Sill_Option 3 & Grade

> D10 Soffit & Electric Box Penetration

> D11 Outside_Inside Corner Treatment

> D12 Aesthetic Reveals Options

OTHER DOCUMENTS

> SPECIFICATION

> AUTOCAD DRAWINGS

> CCMC EVALUATION

2D DETAILS

> 2D DETAIL FULL PACKAGE

> STANDARD WALL SECTION

> D01 Window Header with PVC Uni-Flash

> D02 Window Header with Metal Flashing

> D03 Window Sill without Flashing

> D04 Window Sill with Flashing

> D05 Window Jamb

> D06 Vertical Exp. Joint_Junction with Conc. Wall

> D07 Horizontal Expansion Joint Sealed

> D08 Horizontal Expansion Joint Drained

> D09 Termination at Balcony Deck

> D10 Termination Sloped Roof

> D11 Termination at Concrete Sill Option 1

> D12 Termination at Concrete Sill Option 2

> D13 Termination at Concrete Sill Option 3

> D14 Termination at Grade

> D15 Termination at Soffit

> D16 Exterior Electric Box Penetration

> D17 Outside Corner Treatment

> D18 Aesthetic Reveals

PUCCS EIFS FOR INSULATED CONCRETE FORM (ICF)

PUCCS is continuous insulation cladding that includes a Geometrically Defined Drainage Cavity (GDDC) that is 10 mm deep and 37% open. PUCCS complies with the CAN/ULC-S716.1 EIFS Materials and Systems test standard, PUCCS satisfies the test criteria in National Building Code of Canada Article 3.1.5.5 when tested in accordance with CAN/ULC-S134, and PUCCS satisfies the test criteria in National Building Code of Canada Article 3.2.3.8 when tested in accordance with CAN/ULC-S101. As PUCCS has not been specifically evaluated for use over ICF, such use is subject to approval from the authority having jurisdiction.

DOWNLOAD DOCUMENTS – SPEC – 3D DETAIL– 2D DETAIL– AUTOCAD

Phone:
(787)962-3419

Retail Store:
PR-189 Km 2.6, Caguas,
Puerto Rico 00725

Caribbean Office:
PO Box 361650, San Juan
Puerto Rico 00936-1650

/ BESTBENNERBUILDING.COM BENNERPRODUCTS.COM WEBSITE TAGS /
Aluminum Ceiling | Mineral Fiber Ceiling | Suspension System | Vinyl Flooring | Benner Products | Vinyl Floor | Reflective Insulation | Caguas | Bathroom Partitions | 3D Walls | Acoustical  Ceiling | Drop Ceiling | false ceiling | Main Tee | Cross Tee | Wall Angle | Fastening | Wood floor |Benner Products | marble floor | Caguas | carpet floor | Insulation | Wood Ceilings | Office ceiling | open cell ceiling | Building Materials | Building materials  supplier | against mold | Aluminun Ceiling Color Chart | Aluminun Ceiling Wood Color Chart | free on-line education | efficiency | Benner Products | greenbuild | reciclied materials | products catalog | clean room floor | clean room ceilings | Benner Solar System | cleanroom walls | Building Insulation | duct insulation | wall finishes |  pvc walls | Caguas | exterior finish insulation system | stucco | decorative floor | stone finish | Benner Products | walkways floors | terraces floor | seamless floor | Caguas | pool areas floor | Benner | patios floor | textured  wall | ceramic plaster glazed | venetian finish | anti slip floors | pvc walls | plafones acusticos | Caguas | techos acustico | losas acustica | pisos acusticos | plafones aluminio | vct floor | Puerto Rico | Ponce | aislacion reflectiva | Caguas | aislacion termica | aislacion ducto | aislacion aire | DuROCK |